@article{98115d7322ed41549f1fb220c14dc92b,
title = "Effect of Manifold Design on Flow Distribution in Multichanneled Microfluidic Devices",
author = "B. Mathew and John, \{T. J.\} and H. Hegab and Hisham Hegab",
note = "The effect of channel width and channel spacing on the flow distribution in a microfluidic device with U-type manifolds is numerically analyzed in this paper. Analysis is performed for flow rates between 1 ml/min and 60 ml/min. Flow distribution in a microfluidic device with three different microchannel widths are studied: 50 μm, 100 μm, and 200 μm.",
year = "2009",
month = jan,
day = "1",
doi = "10.1115/FEDSM2009-78531",
language = "American English",
journal = "ASME 2009 Fluids Engineering Division Summer Meeting",
}